Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Radiol ; 53(10): 2054-2059, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37423916

RESUMO

BACKGROUND: Only verbal pregnancy screening is recommended for post-menarcheal females undergoing pelvic radiographs. In contrast, usually, a urine/serum pregnancy test for pelvic computed tomographic (CT) exams is required out of concern for higher radiation exposure. OBJECTIVE: To estimate patient-specific fetus absorbed dose to a potentially pregnant minor from an optimized dose CT of the pelvis for femoral version and surgical planning and provide evidence that such examinations of the pelvis can be performed with only verbal pregnancy screening. METHODS AND METHODS: A retrospective study was performed on 102 female patients between 12-18 years of age (15.4 ± 2.1 years) who underwent optimized dose CT of the pelvis for orthopedic evaluation of femoral version and surgical planning. Optimized CT exams were performed with weight-adjusted kVp and tube current modulation. Patient-specific dose from the optimized dose CT was calculated using the National Cancer Institute Dosimetry System for CT (NCICT) database by matching each patient to a phantom from the NCI non-reference phantom library based on patient sex, weight, and height. The calculated absorbed uterus dose was used as a surrogate for the fetus dose. Furthermore, patient-specific organ doses were used to estimate the effective dose. The strengths of the linear relationships between the dose metrics and patient characteristics were assessed using Pearson correlation coefficients through linear regression. RESULTS: The mean patient-specific effective dose for an optimized dose CT of the pelvis was 0.54 ± 0.20 mSv (range: 0.15-1.22 mSv). The mean estimated absorbed uterine dose was 1.57 ± 0.67 mGy (range: 0.42-4.81 mGy). Both effective dose and estimated uterine dose correlated poorly with patient physical characteristics (R = -0.26; 95% CI: [-0.43, -0.007] for age, R = 0.03; 95% CI: [-0.17, 0.22] for weight) but correlated strongly (R = 0.79, 95% CI: [0.7, 0.85]) with CTDIvol. CONCLUSION: The estimated fetus dose in case of pregnancy was significantly lower than 20 mGy for urine/serum pregnancy screening, suggesting that the pregnancy screening protocols in minors undergoing optimized dose CT require reassessment and may be safely performed by verbal attestation only.


Assuntos
Menores de Idade , Tomografia Computadorizada por Raios X , Gravidez , Humanos , Feminino , Adolescente , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Feto/diagnóstico por imagem , Imagens de Fantasmas , Pelve/diagnóstico por imagem
2.
Invest Radiol ; 58(3): 190-198, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36070536

RESUMO

OBJECTIVES: Hip displacement is the second most common orthopedic problem affecting children with cerebral palsy (CP). Routine radiographic hip surveillance typically involves an anteroposterior (AP) pelvis radiograph. Unfortunately, this imaging protocol is limited by its projectional technique and the positioning challenges in children with CP. Alternatively, hip low-dose computed tomography (LDCT) has been advocated as a more accurate strategy for imaging surveillance as it provides biofidelic details of the hip that is independent of patient positioning. However, the tradeoff is the (presumed) higher radiation dose to the patient. The goal of this study is to estimate patient-specific radiation doses of hip LDCTs and AP pelvis radiographs in CP patients, and perform an intrapatient dose comparison. MATERIALS AND METHODS: A search of our imaging database was performed to identify children with CP who underwent hip LDCT and AP pelvis radiograph within 6 months of each other. The LDCTs were performed using weight-adjusted kVp and tube current modulation, whereas the radiographs were obtained with age-/size-adjusted kVp/mAs. The patient-specific organ and effective doses for LDCT were estimated by matching the patients to a nonreference pediatric phantom library from the National Cancer Institute Dosimetry System for Computed Tomography database with Monte Carlo-based dosimetry. The patient-specific organ and effective doses for radiograph were estimated using the National Cancer Institute Dosimetry System for Radiography and Fluoroscopy with Monte Carlo-based dose calculation. Dose conversion k-factors of dose area product for radiography and dose length product for LDCT were adapted, and the estimation results were compared with patient-specific dosimetry. RESULTS: Our study cohort consisted of 70 paired imaging studies from 67 children (age, 9.1 ± 3.3 years). The patient-specific and dose length product-based effective doses for LDCT were 0.42 ± 0.21 mSv and 0.59 ± 0.28 mSv, respectively. The patient-specific and dose area product-based effective doses for radiography were 0.14 ± 0.09 mSv and 0.08 ± 0.06 mSv, respectively. CONCLUSIONS: The radiation dose for a hip LDCT is ~4 times higher than pelvis radiograph, but it is still very low and poses minimal risk to the patient.


Assuntos
Paralisia Cerebral , Humanos , Criança , Pré-Escolar , Doses de Radiação , Paralisia Cerebral/diagnóstico por imagem , Radiografia , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Método de Monte Carlo
3.
J Endourol ; 35(6): 789-794, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33528298

RESUMO

Background: We wished to determine whether newly available flat panel detector (FPD) c-arms were (1) associated with lower radiation dose during ureteroscopy (URS) than conventional image intensifier (CII) c-arms and (2) to compare fluoroscopic image quality between the units. Materials and Methods: We retrospectively reviewed 44 consecutive patients undergoing URS at a pediatric hospital, with c-arms assigned by availability in the operating room. We performed dosimetry experiments using the same c-arms on standard phantoms. Results: Patient and case characteristics did not differ significantly between the two groups of patients. The median dose in the FPD group was less than a quarter of the dose in the CII group, 0.48 [0.42, 0.97] mGy vs 2.2 [1.1, 3.8] mGy, p < 0.0001. The FPD dose remained at less than one-third of the CII dose accounting for any difference in fluoroscopy time, and remained significant in a multivariate model including fluoroscopy time and patient weight (ß = 2.4, p = 0.007). Phantom studies showed higher image quality for FPDs at all simulated patient sizes, even at lower radiation doses. Conclusions: This is the first report comparing radiation dose from c-arms of image intensifiers and FPDs in adults or children. Use of an FPD during URS was associated with a substantially decreased absorbed dose for patients while simultaneously improving image quality.


Assuntos
Exposição à Radiação , Ureteroscopia , Criança , Fluoroscopia , Humanos , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica , Estudos Retrospectivos
4.
Med Phys ; 48(3): 1299-1306, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33452832

RESUMO

PURPOSE: To develop a scheme to quantitatively assess localization accuracy of tomosynthesis-guided vacuum-assisted breast biopsy apparatus. METHODS: A phantom containing a metallic pellet on a flexible plastic shaft was constructed and was tested in cranio-caudal (CC) and lateral (LAT) arm biopsy geometries following the standard clinical breast biopsy workflow. Three points were manually digitized on tomosynthesis images including: the center of the target, and the tip of the needle in pre- and postfire positions. The needle trajectory was determined and four error metrics were defined: (1) stroke length error (difference between the nominal and measured stroke lengths); (2) Euclidian distance between the target and center of trough (i.e., aperture); (3) longitudinal distance between target and center of trough; and (4) lateral distance between target and needle. The proposed methodology was also evaluated on a breast gel phantom and the complete biopsy procedure, including vacuum-assisted biopsy was performed. RESULTS: Three biopsy geometries were investigated: (i) LAT arm on a prone table unit (Hologic, Affirm Prone), (ii) CC- and (iii) LAT arm in an upright unit (Hologic Affirm Upright). Both biopsy units passed the vendor-provided daily localization accuracy test, with <1 mm nominal error in each dimension. The aforementioned error metrics (1) to (4) were (0.6, 1.8, 0.4, 1.7) mm, (0.4, 4.2, 4.1, 1.1) mm, and (0.3, 2.4, 0.7, 2.3) mm, respectively, for geometry-I, -II, and -III. The gel phantom was tested on the upright unit with lateral arm and the error metrics (1) to (4) were 0.4, 2.5, 0.8, and 2.4 mm respectively. CONCLUSIONS: A framework was developed to evaluate the tomosynthesis-guided breast biopsy localization error, allowing quantitative comparisons between different systems and biopsy configurations. The proposed framework can also be extended to the stereotactic breast biopsy units. We suggest that a quantitative tolerance level for localization accuracy of breast biopsy units be established.


Assuntos
Neoplasias da Mama , Mama , Biópsia por Agulha , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Humanos , Biópsia Guiada por Imagem , Imageamento Tridimensional , Imagens de Fantasmas
5.
Magn Reson Med ; 85(6): 2965-2977, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404069

RESUMO

PURPOSE: To compare transverse relaxation rates of brain metabolites estimated from single-TE PRESS acquisitions with more conventionally derived rates estimated from multiple-TE PRESS acquisitions. METHODS: Single-voxel (8 mL) PRESS data within white matter from 6 subjects were acquired at five different TEs. Transverse relaxation rates R2 of N-acetylaspartate, creatine, and choline were estimated from a single TE using full versus right-side-only sampling of the echo. These R2 values were compared with R2Hahn values obtained from the multiple-TE PRESS acquisitions. RESULTS: Following baseline subtraction and RMS weighting, interindividual mean R2 values from TE = 288 ms magnitude spectra for choline, creatine, and N-acetylaspartate were highly correlated with respective R2Hahn values (r2 = 0.99). Paired individual measurements at this TE showed less correlation (r2 = 0.48), primarily due to the N-acetylaspartate resonance. Using TE = 360 ms data for N-acetylaspartate and 288 ms for choline and creatine resulted in an improved correlation coefficient (r2 = 0.80). The average absolute intra-individual differences in the estimated R2 s between single-TE and Hahn method was 9.6 ± 7.7%. CONCLUSION: For the major brain metabolite singlets, R2Hahn values showed correlations with more fragile measurements of R2 from a single TE that are worthy of interest. Because the left side of long-TE spin echoes is available "for free" from an acquisition perspective, and although the single-TE method for estimating R2 values is associated with lower precision, the reduction in scan time may be clinically helpful.


Assuntos
Encéfalo , Creatina , Ácido Aspártico , Encéfalo/diagnóstico por imagem , Colina , Humanos , Espectroscopia de Ressonância Magnética
6.
NMR Biomed ; 33(6): e4290, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32167612

RESUMO

The goal of this study was to test a new formalism for extracting reversible and irreversible transverse relaxation rates from resonances within typical proton muscle spectra using only a single spin echo as acquired with routine single-voxel, point-resolved echo spectroscopy (PRESS) acquisitions. Single-voxel, non-water-suppressed PRESS acquisitions within the calf muscles of four healthy subjects were performed at 1.5 T using six echo times ranging from 30 to 576 ms. Novel transverse relaxation analyses of water, choline, creatine, and lipid resonances were performed based upon the disparate relaxation sensitivities of the left versus the right sides of spectroscopically sampled spin echoes. Irreversible and reversible transverse relaxation rates R2 and R2 ' were extracted for water, metabolites, and lipids using echo times of 288 ms and longer. The R2 values so obtained were compared with more conventional "gold standard" Hahn values, R2Hahn , evaluated from the echo-time dependence of spectral peak areas generated from right-side sampling alone. Water resonances displayed biexponential Hahn signal decays, consistent with observations of decreasing R2 values with increasing echo time via the new approach. Choline and creatine resonances displayed monoexponential echo-time decays, with R2Hahn values in reasonable agreement with R2 values obtained from the single-echo analyses at the longer echo times. Lipid methylene and methyl R2 values extracted from the new approach were also in reasonable accord with R2Hahn values. Further validation of the technique was provided through PRESS acquisitions on a water phantom to which various levels of gadolinium were added in order to manipulate transverse relaxation rates, yielding excellent agreement between water-resonance R2Hahn and single-echo R2 values. In summary, this work demonstrates the feasibility of measuring reversible and irreversible transverse relaxation rates for individual spectral peaks from single-echo PRESS acquisitions, enabling a reduction in overall scan time relative to the use of multiple acquisitions with varying echo time.


Assuntos
Imageamento por Ressonância Magnética , Músculos/diagnóstico por imagem , Marcadores de Spin , Colina/metabolismo , Creatina/metabolismo , Feminino , Humanos , Lipídeos/química , Masculino , Pessoa de Meia-Idade , Músculos/metabolismo , Imagens de Fantasmas , Fatores de Tempo , Água
7.
Int J Radiat Oncol Biol Phys ; 106(1): 206-215, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31627178

RESUMO

PURPOSE: The current magnetic resonance imaging-computed tomography (MRI-CT) fusion-based workflow for postimplant dosimetry of low-dose-rate (LDR) prostate brachytherapy takes advantage of the superior soft tissue contrast of MRI, but still relies on CT for seed visualization and detection. Recently an MR-only workflow has been proposed that employs standard MR sequences and visualizes conventional implanted seed with positive contrast solely through MR postprocessing. In this work, the novel MR-only based workflow is compared with the clinical CT-MRI fusion approach. METHODS AND MATERIALS: Twenty-four prostate patients with a total of 1775 implanted LDR seeds were scanned using a 3-dimensional multiecho gradient echo sequence on a 3 Tesla MR scanner within 30 days after implantation. Quantitative susceptibility mapping was used for seed visualization. Seeds were automatically segmented and localized on the quantitative susceptibility mapping using convolutional neural network and k-means clustering, respectively. To assess the MR-only seed localization error, CT and MR-derived seed positions were coregistered, and ultimately, the resulting dose-volume histograms were compared. RESULTS: The MR-based seed visualization, segmentation, and localization generated comparable results to the CT-MR registration approach. The accuracy of the MRI-only based seed identification was 99.1%. After a rigid registration between the MR and CT-derived seed centroids, the average localization error was 0.8 ± 0.8 mm. The average prostate D90, V100, V150, and V200 for MRI-only and CT-MR fusion based dosimetry were 114.3 ± 12.5% versus 113.9 ± 11.9%, 95.1 ± 3.7% versus 95.3 ± 3.8%, 54.5 ± 14.5% versus 55.0 ± 13.2% and 22.9 ± 6.8% versus 23.2 ± 6.7%, respectively. No significant differences were observed in 3-dimensional seed positions and dosimetric parameters between MR-only and CT-MR fusion-based workflows (P > 0.2). CONCLUSIONS: The MRI-only LDR postimplant dosimetry is feasible and has very good potential to eliminate the need for CT-based seed identification.


Assuntos
Braquiterapia/métodos , Imageamento por Ressonância Magnética , Imagem Multimodal/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada por Raios X , Fluxo de Trabalho , Algoritmos , Braquiterapia/instrumentação , Estudos de Viabilidade , Gases , Humanos , Radioisótopos do Iodo/administração & dosagem , Masculino , Neoplasias da Próstata/patologia , Radiometria/métodos , Reto/diagnóstico por imagem , Fatores de Tempo
8.
Brachytherapy ; 18(6): 863-874, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31337542

RESUMO

PURPOSE: The lack of positive contrast from brachytherapy seeds in conventional MR images remains a major challenge toward an MRI-only workflow for postimplant dosimetry of low-dose-rate brachytherapy. In this work, the feasibility of our recently proposed MRI-only workflow in clinically relevant scenarios is investigated and the necessary modifications in image acquisition and processing pipeline are proposed for transition to the clinic. METHODS AND MATERIALS: Four prostate phantoms with a total of 321 I-125 implanted dummy seeds and three patients with a total of 168 implanted seeds were scanned using a gradient echo sequence on 1.5 T and 3T MR scanners. Quantitative susceptibility mapping (QSM) was performed for seed visualization. Before QSM, the seed-induced distortion correction was performed followed by edge enhancement. Seed localization was performed using spatial clustering algorithms and was compared with CT. In addition, feasibility of the proposed method on detection of prostatic calcifications was studied. RESULTS: The proposed susceptibility-based algorithm generated consistent positive contrast for the seeds in phantoms and patients. All the 321 seeds in the four phantoms were correctly identified; the MR-derived seeds centroids agreed well with CT-derived positions (average error = 0.5 ± 0.3 mm). The proposed algorithm for seed visualization was found to be orientation invariant. In patient cases, all seeds were visualized and correctly localized (average error = 1.2 ± 0.9 mm); no significant differences between dose volume histogram parameters were found. Prostatic calcifications were depicted with negative contrast on QSM and spatially agreed with CT. CONCLUSIONS: The proposed MRI-based approach has great potential to replace the current CT-based practices. Additional patient studies are necessary to further optimize and validate the workflow.


Assuntos
Algoritmos , Braquiterapia/métodos , Radioisótopos do Iodo/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Implantes de Medicamento , Humanos , Masculino , Neoplasias da Próstata/diagnóstico , Radiometria/métodos
9.
Phys Med Biol ; 64(14): 145013, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31151120

RESUMO

Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR-invisible' metal-based devices. In this study, the feasibility of quantitative susceptibility mapping (QSM) for visualization of some MR-invisible radiation therapy devices was studied. Our recently proposed QSM-based algorithm for brachytherapy seed visualization was modified and the feasibility of the optimized algorithm for visualization of different devices including: brachytherapy seeds, plastic interstitial needles, CT-markers and obturators, and different types of fiducial markers in agar, prostate and meat phantoms were studied. All phantoms were scanned using 3T MR scanner with a 3D multi-echo gradient recalled echo (ME-GRE) pulse sequence. The QSM results in all phantoms were compared to CT images for spatial accuracy of the QSM. The applied post-processing algorithm was found to be insensitive to the seeds' type; also, presence of nearby calcifications had no effect on seed visualization. QSM successfully generated positive contrast for both types of investigated fiducial markers with high spatial accuracy compared to CT. Interstitial needles containing both aluminum-based CT-maker and titanium-based obturators were accurately depicted on the QSM. The proposed QSM-based technique relies on the standard MR pulse sequences and visualize the conventional MR-invisible metallic devices with CT-like positive contrast solely through post-processing. Upon in vivo validation of the technique, QSM may have the potential to replace CT for an MR-only guided radiation therapy.


Assuntos
Braquiterapia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Algoritmos , Meios de Contraste , Humanos , Masculino , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica
10.
Crit Care Med ; 47(4): e349-e357, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30747772

RESUMO

OBJECTIVES: Epinephrine is routinely administered to sudden cardiac arrest patients during resuscitation, but the neurologic effects on patients treated with epinephrine are not well understood. This study aims to assess the cerebral oxygenation and metabolism during ventricular fibrillation cardiac arrest, cardiopulmonary resuscitation, and epinephrine administration. DESIGN: To investigate the effects of equal dosages of IV epinephrine administrated following sudden cardiac arrest as a continuous infusion or successive boluses during cardiopulmonary resuscitation, we monitored cerebral oxygenation and metabolism using hyperspectral near-infrared spectroscopy. SETTINGS: A randomized laboratory animal study. SUBJECTS: Nine healthy pigs. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Our study showed that although continuous epinephrine administration had no significant impact on overall cerebral hemodynamics, epinephrine boluses transiently improved cerebral oxygenation (oxygenated hemoglobin) and metabolism (cytochrome c oxidase) by 15% ± 6.7% and 49% ± 18%, respectively (p < 0.05) compared with the baseline (untreated) ventricular fibrillation. Our results suggest that the effects of epinephrine diminish with successive boluses as the impact of the third bolus on brain oxygen metabolism was 24.6% ± 3.8% less than that of the first two boluses. CONCLUSIONS: Epinephrine administration by bolus resulted in transient improvements in cerebral oxygenation and metabolism, whereas continuous epinephrine infusion did not, compared with placebo. Future studies are needed to evaluate and optimize the use of epinephrine in cardiac arrest resuscitation, particularly the dose, timing, and mode of administration.


Assuntos
Epinefrina , Parada Cardíaca , Oxigênio , Animais , Reanimação Cardiopulmonar , Circulação Cerebrovascular , Epinefrina/administração & dosagem , Epinefrina/farmacologia , Parada Cardíaca/sangue , Parada Cardíaca/tratamento farmacológico , Oxigênio/sangue , Oxigênio/metabolismo , Espectrofotometria Infravermelho , Suínos
11.
Radiother Oncol ; 129(3): 540-547, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30243670

RESUMO

BACKGROUND AND PURPOSE: Permanent seed brachytherapy is an established treatment option for localized prostate cancer. Currently, post-implant dosimetry is performed on CT images despite challenging target delineation due to limited soft tissue contrast. This work aims to develop an MRI-only workflow for post-implant dosimetry of prostate brachytherapy seeds. MATERIAL AND METHODS: A prostate mimicking phantom containing twenty stranded I-125 dummy seeds and calcifications was constructed. A three-dimensional gradient-echo MR sequence was employed on 3T and 1.5T MR scanners. An optimized quantitative susceptibility mapping (QSM) technique was applied to generate positive contrast for the seeds and calcifications. Seed numbers, centroids, and orientations were determined using unsupervised machine learning algorithms (K-means and K-medoids clustering). The geometrical seed positions and the resulting dose distribution were compared to the clinical CT-based approach. RESULTS: The optimized QSM-based method generated high quality positive contrast for the seeds that were significantly different from that for calcifications and could be easily differentiated by thresholding. The estimated seed centroids from both 3T and 1.5T MR data were in perfect agreement with the standard CT-based seed detection algorithm (maximum difference of 0.7 mm). The estimated seed orientations were highly correlated with the actual orientations (R > 0.98). CONCLUSIONS: The proposed MRI-based workflow enabling an accurate and robust means to localize the seeds (position and orientation) upon validation on complex seed configurations, has the potential to replace the current widely practiced CT-based workflow.


Assuntos
Braquiterapia/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Aprendizado de Máquina não Supervisionado , Meios de Contraste , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Imagens de Fantasmas , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
12.
Circ J ; 81(6): 879-887, 2017 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-28302943

RESUMO

BACKGROUND: Maintaining cerebral oxygen delivery and metabolism during cardiac arrest (CA) through resuscitation is essential to improve the survival rate while avoiding brain injury. The effect of CA and cardiopulmonary resuscitation (CPR) on cerebral and muscle oxygen delivery and metabolism is not clearly quantified.Methods and Results:A novel hyperspectral near-infrared spectroscopy (hNIRS) technique was developed and evaluated to measure cerebral oxygen delivery and aerobic metabolism during ventricular fibrillation (VF) CA and CPR in 14 pigs. The hNIRS parameters were measured simultaneously on the dura and skull to investigate the validity of non-invasive hNIRS measurements. In addition, we compared the hNIRS data collected simultaneously on the brain and muscle. Following VF induction, oxygenated hemoglobin (HbO2) declined with a 9.9 s delay and then cytochrome-c-oxidase (Cyt-ox) decreased on average 4.4 s later (P<0.05). CPR improved cerebral metabolism, which was reflected by an average 0.4 µmol/L increase in Cyt-ox, but had no significant effect on HbO2, deoxygenated hemoglobin (HHb) and tissue oxygen saturation (tSO2). Cyt-ox had greater correlation with HHb than HbO2. Muscle metabolism during VF and CPR was significantly different from that of the brain. The total hemoglobin concentration (in the brain only) increased after ~200 s of untreated CA, which is most likely driven by cerebral autoregulation through vasodilation. CONCLUSIONS: Overall, hNIRS showed consistent measurements of hemodynamics and metabolism during CA and CPR.


Assuntos
Reanimação Cardiopulmonar , Circulação Cerebrovascular , Oxigênio/sangue , Espectrofotometria Infravermelho , Vasodilatação , Fibrilação Ventricular , Animais , Complexo IV da Cadeia de Transporte de Elétrons/sangue , Feminino , Parada Cardíaca/sangue , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Hemoglobinas/metabolismo , Suínos , Fibrilação Ventricular/sangue , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
13.
Biomed Opt Express ; 7(4): 1323-35, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27446658

RESUMO

Recent technological advancements in optical spectroscopy allow for the construction of hyperspectral (broadband) portable tissue oximeters. In a series of our recent papers we have shown that hyperspectral NIRS (hNIRS) has similar or better capabilities in the absolute tissue oximetry as frequency-domain NIRS, and that hNIRS is also very efficient in measuring temporal changes in tissue hemoglobin concentration and oxygenation. In this paper, we extend the application of hNIRS to the measurement of event-related hemodynamic and metabolic functional cerebral responses during simulated driving. In order to check if hNIRS can detect event-related changes in the brain, we measured the concentration changes of oxygenated (HbO2) and deoxygenated (HHb) hemoglobin and of the oxidized state of cytochrome c oxidase, on the right and left prefrontal cortices (PFC) simultaneously during simulated driving on sixteen healthy right-handed participants (aged between 22-32). We used our in-house hNIRS system based on a portable spectrometer with cooled CCD detector and a driving simulator with a fully functional steering wheel and foot pedals. Each participant performed different driving tasks and participants were distracted during some driving conditions by asking general knowledge true/false questions. Our findings suggest that more complex driving tasks (non-distracted) deactivate PFC while distractions during driving significantly activate PFC, which is in agreement with previous fMRI results. Also, we found the changes in the redox state of the cytochrome C oxidase to be very consistent with those in the concentrations of HbO2 and HHb. Overall our findings suggest that in addition to the suitability of absolute tissue oximetry, hyperspectral NIRS may also offer advantages in functional brain imaging. In particular, it can be used to measure the metabolic functional brain activity during actual driving.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...